Setting the Electronic Shutter
48
Chapter 3 Adjustments and Settings
To set no color temperature
Select “-----” with “
Electrical CC<C>” or
Electrical CC<D>” selected.
When the assignable switch is pressed, the
setting for that position is not displayed. For
example, if “-----” is set for one position, then
switching between the remaining three
positions is carried out.
3 Repeat step 2 as required.
4 Assign the electrical CC filter switching
function (ELECTRICAL CC) to an
assignable switch (see page 151).
White balance memory
Values stored in memory are held until the white
balance is next adjusted even when the camcorder
power is turned off.
The camcorder has two white balance memories,
A and B. You can automatically save adjustment
values for each ND filter in the memory that
corresponds to the WHITE BAL switch setting
(A or B). The camcorder has four built-in ND
filters, allowing you to save a total of eight
adjustment values (4 × 2). However, the contents
of the memories are not linked to ND filter
settings in the following cases.
When the number of memories allocated to
each of A and B is limited to one by setting
“OPERATION” > “White Setting” > “Filter
White Memory” in the setup menu to “Off.”
When the electrical CC filter switching function
has been assigned to an assignable switch, or
when a remote control unit has been connected.
(In these cases, the contents of white balance
memory are linked to electrical CC filter
positions (A to D).)
Also, when “OPERATION” > “White Setting” >
“White Switch<B>” in the setup menu is set to
“ATW (Auto Tracing White Balance),” and the
WHITE BAL switch is set to B, the ATW
function is activated to automatically adjust the
white balance of the picture being shot for
varying lighting conditions.
Note
While the ATW function is activated, the color
temperature of the subject may differ from the color
temperature that is displayed on the viewfinder screen.
Standard mode
Select this mode for shooting fast-moving
subjects with little blurring.
You can set the shutter speed in one of two shutter
modes: Speed mode, in which the speed is set in
seconds, and Angle mode, in which the speed is
set in degrees.
Speed mode
a) This speed cannot be selected when the camcorder is
in Slow & Quick Motion mode and “OPERATION” >
“Rec Function” > “Frame Rate” in the setup menu is
set to a value that is greater than the system frequency.
Angle mode
180°, 90°, 45°, 22.5°, and 11.25°
ECS (Extended Clear Scan) mode
Select this mode for obtaining images with no
horizontal bands of noise when shooting subjects
such as monitor screens.
As shown in the following tables, the range of
shutter speeds that can be set varies depending on
whether the Slow & Quick Motion (S&Q)
function is on or off.
Setting the Electronic
Shutter
Shutter Modes
System
frequency
Shutter speed (unit: seconds)
59.94i
59.94P
50i
50P
1
/
60,
1
/
100,
1
/
120
,
1
/
125
,
1
/
250
,
1
/
500
,
1
/
1000
,
1
/
2000
29.97P
1
/
40
a)
,
1
/
50
a)
,
1
/
60
,
1
/
100,
1
/
120
,
1
/
125
,
1
/
250
,
1
/
500
,
1
/
1000
,
1
/
2000
25P
1
/
33
a)
,
1
/
50
a)
,
1
/
60,
1
/
100
,
1
/
120,
1
/
125
,
1
/
250
,
1
/
500
,
1
/
1000
,
1
/
2000
23.98P
1
/
32
a)
,
1
/
48
a)
,
1
/
50
a)
,
1
/
60
,
1
/
96
,
1
/
100
,
1
/
120,
1
/
125
,
1
/
250
,
1
/
500
,
1
/
1000
,
1
/
2000